Celadon Inc. |
|
|
RCV-5000 IR to RS-232 Output Table |
|
|
Device: Feral - Key West QS440/1 Quad Video Switcher |
|
|
|
|
|
Infrared Remote Control: Philips PRONTO, Niles Intellicontrol |
|
|
Infrared Code Format: NEC - Device ID: 7B02 |
|
|
Infrared Pronto Data File(s): See "IR Code Read Me - RCV-5000.txt" for complete description |
|
Infrared Receiver: Celadon RCV-5000 Infrared to RS-232 Receiver |
|
|
RCV-5000 Data File: feral1_r.hex |
|
|
Data: 9600 Baud, 8, N, 1, ASCII Output |
|
|
Standard Transmit and Receive pinout |
|
|
|
|
|
|
|
|
|
|
|
Command |
Pronto Button |
RCV-5000 Output |
Set Background Black |
0 |
aB+<cr> |
Set Background White |
1 |
aB-<cr> |
Set Chroma Value - Increment |
2 |
aC1+<cr> |
Set Chroma Value - Decrement |
3 |
aC1-<cr> |
Set Chroma Value - Normalize |
4 |
aC1@<cr> |
Freeze Routine - Freeze ON - CH1 |
5 |
aE1+<cr> |
Freeze Routine - Freeze ON - CH2 |
6 |
aE2+<cr> |
Freeze Routine - Freeze ON - CH3 |
7 |
aE3+<cr> |
Freeze Routine - Freeze ON - CH4 |
8 |
aE4+<cr> |
Freeze Routine - Freeze OFF - CH1 |
9 |
aE1-<cr> |
Freeze Routine - Freeze OFF - CH2 |
10 |
aE2-<cr> |
Freeze Routine - Freeze OFF - CH3 |
11 |
aE3-<cr> |
Freeze Routine - Freeze OFF - CH4 |
12 |
aE4-<cr> |
Hue Value Routine - Increment |
13 |
aH1+<cr> |
Hue Value Routine - Decrement |
14 |
aH1-<cr> |
Hue Value Routine - Normalize |
15 |
aH1@<cr> |
Luminance Value Routine - Increment |
16 |
aL1+<cr> |
Luminance Value Routine - Decrement |
17 |
aL1-<cr> |
Luminance Value Routine - Normalize |
18 |
aL1@<cr> |
Priority Command - ZAP 1 |
19 |
aP@0<cr> |
Priority Command - Channel 1 |
20 |
aP@1<cr> |
Priority Command - Channel 2 |
21 |
aP@2<cr> |
Priority Command - Channel 3 |
22 |
aP@3<cr> |
Priority Command - Channel 4 |
23 |
aP@4<cr> |
Priority Command - ZAP 2 |
24 |
aP@5<cr> |
Recall from EEPROM Routine - Current Channel Setting |
25 |
aR@C<cr> |
Recall from EEPROM Routine - Settings for All Channels |
26 |
aR@A<cr> |
Recall from EEPROM Routine - Initial Settings |
27 |
aR@I<cr> |
Recall from EEPROM Routine - Normal Settings |
28 |
aR@N<cr> |
Recall from EEPROM Routine - Power On Reset Settings |
29 |
aR@P<cr> |
Store to EEPROM Routine - Current Channel Setting |
30 |
aT@C<cr> |
Store to EEPROM Routine - Settings for All Channels |
31 |
aT@I<cr> |
Store to EEPROM Routine - Initial Settings |
32 |
aT@P<cr> |
Store to EEPROM Routine - Normal Settings |
33 |
aT@N<cr> |
Store to EEPROM Routine - Power On Reset Settings |
34 |
aT@A<cr> |
Set Setup Value Routine - Increment |
35 |
aS1+<cr> |
Set Setup Value Routine - Decrement |
36 |
aS1-<cr> |
Set Setup Value Routine - Normalize |
37 |
aS1@<cr> |
Active Channel Select - Matrix OCF |
38 |
av0<cr> |
Active Channel Select - Scaler Channel 1 |
39 |
av1<cr> |
Active Channel Select - Scaler Channel 2 |
40 |
av2<cr> |
Active Channel Select - Scaler Channel 3 |
41 |
av3<cr> |
Active Channel Select - Scaler Channel 4 |
42 |
av4<cr> |
Select and Update crosspoint for MAX456 - input1/output1 |
43 |
ax11<cr> |
Select and Update crosspoint for MAX456 - input1/output2 |
44 |
ax12<cr> |
Select and Update crosspoint for MAX456 - input1/output3 |
45 |
ax13<cr> |
Select and Update crosspoint for MAX456 - input1/output4 |
46 |
ax14<cr> |
Select and Update crosspoint for MAX456 - input2/output1 |
47 |
ax21<cr> |
Select and Update crosspoint for MAX456 - input2/output2 |
48 |
ax22<cr> |
Select and Update crosspoint for MAX456 - input2/output3 |
49 |
ax23<cr> |
Select and Update crosspoint for MAX456 - input2/output4 |
50 |
ax24<cr> |
Select and Update crosspoint for MAX456 - input3/output1 |
51 |
ax31<cr> |
Select and Update crosspoint for MAX456 - input3/output2 |
52 |
ax32<cr> |
Select and Update crosspoint for MAX456 - input3/output3 |
53 |
ax33<cr> |
Select and Update crosspoint for MAX456 - input3/output4 |
54 |
ax34<cr> |
Select and Update crosspoint for MAX456 - input4/output1 |
55 |
ax41<cr> |
Select and Update crosspoint for MAX456 - input4/output2 |
56 |
ax42<cr> |
Select and Update crosspoint for MAX456 - input4/output3 |
57 |
ax43<cr> |
Select and Update crosspoint for MAX456 - input4/output4 |
58 |
ax44<cr> |
Select and Update crosspoint for MAX456 - Return Crosspoint Setting |
59 |
ax@? |
Select and Update crosspoint for MAX456 - Store xpoints to EEPROM |
60 |
ax@s |
Select and Update crosspoint for MAX456 - Recall xpoints from EEPROM |
61 |
ax@r |
Video Control Routine - Video ON |
62 |
aV+<cr> |
Video Control Routine - Video OFF |
63 |
aV-<cr> |
Video Control Routine - Video Status Inquiry 1 on, 0 off |
64 |
aV?<cr> |
Video Control Routine - Video Composite |
65 |
aVC<cr> |
Video Control Routine - Video Component |
66 |
aVS<cr> |
Make Channel Inactive |
67 |
aV0<cr> |
Make Channel Active |
68 |
aV1<cr> |
|
|
|
|
|
|
Celadon, Inc. |
|
|
500 Tamal Plaza, Suite 520 |
|
|
Corte Madera, CA 94925 |
|
|
Sales: (415) 472-1177 x201 |
|
|
Main Tel: (415) 472-1177 |
|
|
Main Fax: (415) 472-1179 |
|
|
sales@remote-design.com |
|
|